shanghai san-凯时娱乐

sx726 portable conductivity/dissolved oxygen meter
    ● double-parameter meter, equipped with conductivity electrode and dissolved oxygen electrode, automatic identification of electrode by meter.
    ●built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, automatic power-off and low voltage display.
    ● automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: europe and america series and china series.
    ● adopt advanced conductivity measurement technology, use conductivity electrode of constant k=1, only need one point calibration and meet the measurement precision requirement of 0.5μs/cm ~ 200 ms/cm.
    ● ability to switch among conductivity, tds, salinity and resistivity. multinomial calculation for tds and salinity to ensure the conversion precision of the full scale.
    ● conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
    ● measurement mode of dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
    ● new polarographic type dissolved oxygen electrode can measure temperature, salinity and dissolved oxygen simultaneously, equipped with special dissolved oxygen electode calibration set, polarization only for 3~5 min.
    ● meter meets ip57 rating, equipped with calibration solution and portable case.
more


sx736 sx736portable ph/conductivity/do meter
    ● multi-parameter meter, equipped with ph electrode, conductivity electrode and dissolved oxygen electrode, automatic identification of electrode by meter.
    ● built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, self-diagnose information, automatic power-off and low voltage display.
    ● automatic identification of 13 ph standard buffer solutions, three options of standard buffer solutions: europe and america series, nist series and china series.
    ● able to set ph measurement modes of high purity water and pure water with ammonia.
    ● automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: europe and america series and china series.
    ● adopt advanced conductivity measurement technology, use conductivity electrode of constant k=1, only need one point calibration and meet the measurement precision requirement of 0.5μs/cm ~ 200 ms/cm.
    ●ability to switch among conductivity, tds, salinity and resistivity. multinomial calculation for tds and salinity to ensure the conversion precision of the full scale.
    ● conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
    ● measurement mode of dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
    ● new polarographic type dissolved oxygen electrode can measure temperature, salinity and dissolved oxygen simultaneously, equipped with special dissolved oxygen electode calibration set, polarization only for 3~5 min.
    ●meter meets ip57 waterproof rating, equipped with calibration solution and portable case.
more


sx751 portable ph/orp/conductivity/do meter

    ● built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, self-diagnose information, automatic power-off and low voltage display.

    ●multi-parameter meter, equipped with ph electrode, orp electrode, conductivity electrode and dissolved oxygen electrode, automatic identification of electrode by meter.
    ●automatic identification of 13 ph standard calibration solutions, three options of standard buffer solutions: europe and america series, nist series and china series.
    ● able to set ph measurement modes of high purity water and pure water with ammonia.
    ● automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: europe and america series and china series.
    ● adopt advanced conductivity measurement technology, use conductivity electrode of constant k=1, only need one point calibration and meet the measurement precision requirement of 0.5μs/cm ~ 200 ms/cm.
    ● ability to switch among conductivity, tds, salinity and resistivity. multinomial calculation for tds and salinity to ensure the conversion precision of the full scale.
    ●conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
    ●measurement mode of dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
    ●new polarographic type dissolved oxygen electrode can measure temperature, salinity and dissolved oxygen simultaneously, equipped with special dissolved oxygen electode calibration set, polarization only for 3~5 min.
    ● meter meets ip57 waterproof rating, equipped with calibration solution and portable case.
more


mp521 lab ph/conductivity meter

    ● the most widely used ph conductivity double-parameter measurement meter.

    ●meter meets with the requirement of international glp standards. its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, rs-232 output, function setting and self-diagnose etc.
    ● there are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
    ● automatically recognize ph buffer solution. user can choose anyone from three series of standard buffer solutions: europe & usa series, nist series and china series.
    ●adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (k=1), it can meet measuring accuracy requirement for range within 0.5μs/cm ~ 200ms/cm by using only one-point calibration.
    ● can switch conductivity, tds, salinity and resistivity.
    ● meter has the only product serial number.
    ● dustproof and waterproof meter meets ip54 standards. all sockets are seal protected by the silica gel caps.
more