shanghai san-凯时娱乐

sx725 portable ph/dissolved oxygen meter
    the most cost effective portable ph dissolved oxygen double-parameter meter, suited for industrial and mining factories, power plant, aquaculture and environmental protection field, especially suited in field and on-site.




● built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, self-diagnose information, automatic power-off and low voltage display.
● double-parameter meter, equipped with ph electrode and dissolved oxygen electrode, automatic identification of electrode by meter.
● automatic identification of 13 ph standard buffer solutions, three options of standard buffer solutions: europe and america series, nist series and china series.
● able to set ph measurement modes of high purity water and pure water with ammonia.
● measurement mode of dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
● new polarographic type dissolved oxygen electrode can measure temperature, salinity and dissolved oxygen simultaneously, equipped with special dissolved oxygen electode calibration set, polarization only for 3~5 min.
● meter meets ip57 waterproof rating, equipped with calibration solution and portable case.

category product name basic features and specifications
ph

measuring range

(-2.00 ~ 19.99)ph

resolution

0.1/0.01 ph

accuracy

meter:±0.01ph; overall: ±0.02ph

input current

≤2×10-12 a

input impendance

≥1×1012 ω

stability

±0.01 ph/3h
temp. compensation range (0 ~ 100)℃(automatic)
orp

measuring range (mv/orp/eh)

-1999mv ~ 0 ~ 1999mv

resolution

1mv

accuracy

meter:±0.1% fs, overall: ±15mv
dissolved oxygen

measuring range

(0 ~ 40.00)mg/l(ppm) (0 ~ 200.0)%

resolution

0.1/0.01 mg/l(ppm) 1/0.1 %

accuracy

meter:±0.10 mg/l, overall:±0.40 mg/l

response time

≤30 s(25℃, 90%response)
residual current ≤0.1 mg/l
temp. compensation range (0 ~ 45)℃(automatic)
salinity compensation range (0 ~ 45)ppt(automatic)

atmospheric pressure compensation range

(66 ~ 200)kpa (manual)

automatic calibration

air saturated by water; water saturated by air

electrode type

polarogram type
other technical parameters

data storage

200 groups
storage content series number, measuring value measuring unit and temperature,

power

two aa batteries (1.5v x2)

size and weight

meter:(65×120×31)mm/180g;suitcase: (360×270×76)mm/1.6kg
quality and safety certification iso9001:2000, ce and cmc
working condition

environment temperature

5 ~ 35 ℃(0.01grade)

environmental humidity

≤85%

ip rating

ip57 dustproof and waterproof

1. model sx725 ph / mv / do meter 1set
2. 201t-s plastic ph/atc three-in-one combined electrode 1pcs
3. do500 do electrode 1pcs
4. ph standard buffer solution( ph4.00, ph7.00 and ph10.01/50ml) 1btl/each
5. do503 membrane cap (do electrode use) 3个
6. do502 do electrode inner solution (30ml) 1pcs
7. cathode polishing paper 1pcs
8. screw driver 1pcs
9. spare aa batteries 2pcs
10. operation manual 1pcs
11. carrying case 1unit

accessory category

description

specifications

ph combination electrode

201t-s plastic three-in-one ph electrode

measure ph and temperature simultaneously, atc, suited for general ph measurement, 8 pin conncetor.

2503dt-s glass three-in-one combintion ph electrode

atc, suited for ph measurement of solution under low temperature and pure water, 8 pin connector.

glass flow cell

match 2503dt-s electrode.

orp combination electrode

301pt-s plastic orp combination electrode

suited for general orp measurement, 8 pin connector.

do electrode

do500 do electrode

polargrafic do electrode, suited for application in lab and field, 8 pin connector.

do electrode accessory

do503 do electrode membrane cap

combined membrane cap, special for do500 do electrode, specification: 3 units per group.

do502 do electrode electrolyte

supplement electrolyte, special for do500 do electrode, specification: 30ml/bottle.

do501 negative electrode polishing paper

polishing paper,special for cleaning negative electrode of do500 do electrode, specification:2 pcs/group.

ph buffer

ph4.00 buffer

500ml/250ml/50ml(bottle)

ph6.86 buffer

500ml/250ml/50ml(bottle)

ph9.18 buffer

500ml/250ml/50ml(bottle)

ph7.00 buffer

500ml/250ml/50ml(bottle)

ph10.01 buffer

500ml/250ml/50ml(bottle)

electrode soaking solution

ph(orp)combination electrode soaking solution

500ml/250ml/50ml(bottle)

orp standard solution

222 mv orp standard solution

250ml/100ml/50ml(bottle)

portable case

small portable case(255×210×50)mm

match single electrode.

big portable case(360×270×76)mm

match multi- electrode