shanghai san-凯时娱乐

mp523 ph/ise meter
    suitable for scientific research, biotechnology, pharmaceutical and food areas such as conventional high-precision ph measurements and ion concentration measurements (please choose the appropriate ion electrode according to need.)




●meter meets with the requirement of international glp standards. its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, rs-232 output, function setting and self-diagnose etc.
●there are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
● automatically recognize 13 kinds of ph buffer solution. user can choose anyone from four series of standard buffer solutions: europe & usa series, nist series, china series and self-defined series
● high purified water and ammonia added purified water ph measuring mode can be set up, especially suitable for electric power and petrochemical industry
● with eh redox potential measuring mode can directly display orp value which against standard potential of hydrogen electrode.
● there are 10 kinds of common ions can be selected in the ion concentration measuring mode, user also can self-define other ions.
● can switch 4 kinds of concentration unit : px, mol/l, mg/l and ppm.
● meter has the only product serial number.
●dustproof and waterproof meter meets ip54 standards. all sockets are seal protected by the silica gel caps.

ph
measuring range
resolution
accuracy
input current
input impendance
stability
temp. compensation range
(-1.999 ~ 19.999)ph
0.1/0.01/0.001 ph
meter:±0.002 ph, connect meter with electrode:±0.01ph
≤1×10-12 a
≥3×1012 ω
±0.002 ph/3h
(0 to 100) ℃(automatic or manual)
mv
measuring range(mv/orp/eh)
resolution
accuracy
-1999.9mv ~ 0 ~ 1999.9mv
0.1mv
±0.03% fs
ion concentration
measuring range
display unit
accuracy
temp. compensation range
0.00 ~ 14.00 px
px、mol/l、mg/l、ppm
meter:±0.5 % reading(monovalent), ±1.0 % reading (bivalent)
0 to 60 ℃(automatic or manual)
temperature
measuring range
resolution
accuracy
-10℃~ 110℃
0.1℃
5~ 60℃range:±0.4℃  other range:±0.8℃
other technical parameters:
data storage
storage content
 
power
communication connector
size and weight
quality and safety certification
300 groups
measuring value series number, measuring value, temperature, atc or mtc state, measuring date and time
dc9v/300ma
rs232
160 × 190 × 70mm/880g
iso9001:2008, ce and cmc
working condition
environment temperature
environmental humidity
ip rating
5 ~ 35 ℃(0.01grade) 15 ~ 30 ℃(0.001grade)
≤75%
ip54 dustproof and waterproof

1. model mp523 ph/ise meter 1set
2. model 602 flexible electrode holder 1pc
3. model 901 intelligent stirrer 1set
4. 201t-m plastic ph/atc three-in-one combination electrode 1pc
5. 2503-c glass ph combination electrode 1pc
6. mp500 temperature electrode 1pc
7. model 6213 double salt bridge reference electrode 1pc
8. ph standard buffer solution(ph4.00, ph7.00 and ph10.01/50ml) 1btl/each
9. 9v power adapter(meter use) 1pc
10. 6v power adapter(stirrer use) 1pc
11. b628 stirring bead 3pc
12. aa battery 4 units
13. rs-232 communication cable 1pc
14. mp523 communication software disk 1pc
15. operation manual 1unit
16. brief operation instruction 1unit
17. packing list 1pc

accessory categry
description
specifications

ph combination electrode

201-c plastic combination ph electrode

suitable for routine ph measurements, widely used, bnc connector。

200-c plastic combination ph electrode

suitable for routine ph measurements, long continuous, high precision, bnc plug.

206-c plastic combination ph electrode

smaller diameter electrode, suitable for small diameter container in a test, bnc connector

201t-m plastic three-in-one combination ph electrode

simultaneous measurement of ph and temperature, automatic temperature compensation, bnc rca plugs.

2501-c glass combination ph electrode

for precise ph test, routine laboratory use, bnc plug.

2503-c glass combination ph electrode

for precise ph test, used to measure complex samples, bnc plug.

2503d-c glass combination ph electrode

for low-temperature solution and pure water ph measurement, bnc plug.

2503g-c glass combination ph electrode

suitable for high temperature solution ph measurements, bnc plug

2503s-c glass combination ph electrode

for acid and high-temperature solution ph measurements, bnc plug.

2015p-c plane combination ph electrode

for the surface and trace solution ph measurement, bnc plug.

ion electrode
7801 sodium ion electrode
used to test the concentration of sodium ion,bnc plug
ca501 calcium composite electrode
used for testing calcium concentration,bnc plug
calcium electrode probe
used with ca501 electrode
f502 fluoride electrode
used to test fluoride concentration,bnc plug
cl502 chloride electrode
used to test the concentration of chloride ion,bnc plug
br502 bromide electrode
used to test the concentration of bromide ion,bnc plug
i502 iodide electrode
used to test the concentration of iodide ion,bnc plug
cu502 copper electrode
used to test the copper concentration,bnc plug
k502 potassium electrode
used to test the concentration of potassium ion,bnc plug
no502 nitrate electrode
used to test the concentration of nitrate ion,bnc plug
nh501 ammonia electrode
used to test the ammonia concentration,bnc plug

reference electrode

6211 reference electrode

suitable for routine measurements, banana plugs.

6212 reference electrode

equipped with the 7801 sodium ion electrode, banana plugs

6213 reference electrode

the first and second salt bridge solution can be chosen, for all measurement occasions, banana plugs.

6215 reference electrode

most ion electrode for supporting the use, banana plugs

orp composite electrode

301pt-c plastice orp combination electrode

orp measurement for conventional, wide range of uses, bnc plug

3501pt –c glass orp combination electrode

orp measurement of routine laboratory, test stability, fast response, bnc plug

temperature electrode
mp500 temperature electrode
stainless steel housing, fast response, high accuracy, rca plugs
ph buffer

ph4.00 buffer

500ml/250ml/50ml(bottle)

ph6.86 buffer

500ml/250ml/50ml(bottle)

ph7.00 buffer

500ml/250ml/50ml(bottle)

ph9.18 buffer

500ml/250ml/50ml(bottle)

ph10.01 buffer

500ml/250ml/50ml(bottle)

ion standard solution
 
10-1 mol/l na standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l ca2 standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l f- standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l cl- standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l br- standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l i- standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l k standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l cu2 standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l ammonium ion standard solution
500ml/250ml/100ml(bottle)
10-1 mol/l no3 standard solution
500ml/250ml/100ml(bottle)
electrode soaking
ph(orp)combination electrode soaking solution
500ml/250ml/100ml(bottle)
10-5 mol/l sodium ion electrode soaking solution
equipped with 7801sodium electrode . 500ml/250ml/100ml(bottle)
electrode add liquid

3.5mol/l kcl(agclsaturated) reference solution

250ml/50ml/30ml(bottle)

1mol/lpotassium nitrate (kno3) reference solution

for chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250ml/100ml/30ml(bottle)

1mol/l sodium chloride (nacl) reference solution

test for potassium, and equipped with 6215 reference electrode,250ml/100ml/30ml(bottle)

0.1mol/l cesium chloride (cscl) reference solution

test for sodium,and equipped with 6212 reference electrode,250ml/100ml/30ml(bottle)

ammonia electrode inner solution

test for ammonium ion, and equipped with nh501 ammonia electrode,250ml/100ml/30ml (bottle)

calciumelectrode inner solution

equipped with ca501 calcium electrode, 250ml/100ml/30ml(bottle)

electrode add liquid
3.5mol/l kcl(agclsaturated) reference solution
500ml/250ml/100ml(bottle)
1mol/lpotassium nitrate (kno3) reference solution
for chlorine, bromine, iodine and copper ion test, and equipped with 6215 reference electrode, 250ml/100ml/30ml(bottle)
1mol/l sodium chloride (nacl) reference solution  
test for potassium, and equipped with 6215 reference electrode,250ml/100ml/30ml(bottle)
0.1mol/l cesium chloride (cscl) reference solution 
test for sodium,and equipped with 6212 reference electrode,250ml/100ml/30ml(bottle)
ammonia electrode inner solution 
test for ammonium ion, and equipped with nh501 ammonia electrode ,250ml/100ml/30ml(bottle)
calcium electrode inner solution
equipped with ca501 calcium electrode, 250ml/100ml/30ml(bottle)
orp standard solution
222 mv orp standard solution
250ml/100ml/50ml(bottle)
electrode holder

model 602 flexible electrode holder

nice appearance of the arc-type bracket, you can turn 360 degrees and vertical lift

model 601stirring type electrode holder

the electrode holder and magnetic stirrer combination of new products.

model 600 electrode holder

cheap simple electrode holder